تخطي إلى التنقل الرئيسي تخطي إلى البحث تخطي إلى المحتوى الرئيسي

Analysis of biomagnetic blood Carreau hybrid nanofluid flow in stenotic arteries with motile gyrotactic microorganisms: Response surface optimisation

  • Maddina Dinesh Kumar
  • , P. Jayasri
  • , José Luis Díaz Palencia
  • , P. Durgaprasad
  • , Ali J. Chamkha
  • , C. S.K. Raju*
  • *المؤلف المقابل لهذا العمل
  • Department of Mathematics and Education
  • Madrid Open University
  • Department of Mathematics
  • B.V. Raju Institute of Technology
  • Vellore Institute of Technology
  • Kuwait College of Science and Technology
  • RTA Centre for Science Innovation
  • RV University

نتاج البحث: Article › مراجعة النظراء

10 اقتباسات (Scopus)

ملخص

Cardiovascular diseases remain a leading cause of death globally, with stenosis playing a significant role in their development. Blood flow dynamics within stenosed arteries are intricate and influenced by various factors, including nanoparticles and microorganisms. This study actively investigates the flow behaviour of biomagnetic blood Carreau tetra hybrid nanofluid within stenotic arteries containing motile gyrotactic microorganisms through response surface optimisation. The formulation is rooted in the Carreau model, elucidating non-Newtonian fluid behaviours, incorporating the Lorentz force to address the magnetic field effects, and integrating the convective-diffusion equation to model microorganism transport. We derived numerical solutions using the built-in solver in MATLAB, i.e. ODE45. The computational domain encompasses a two-dimensional stenosed artery featuring a sinusoidal stenosis profile. We characterise the inlet conditions with fully developed Carreau fluid flow accompanied by a uniform magnetic field, while the outlet conditions involve a zero-pressure gradient. The arterial walls are assumed to be rigid and non-slip. Response surface optimisation employs the central composite design method to minimise pressure drop across the stenosis, yielding optimal values for input parameters, including magnetic field strength, nanoparticle concentration, and microorganism concentration. The study discerns the substantial influence of nanoparticles and microorganisms on flow behaviour within stenosed arteries, underscoring the efficacy of response surface optimisation in flow behaviour optimisation. Limitations include assumptions of steady flow and simplifications in artery geometry, suggesting avenues for future exploration, particularly in transient flow dynamics and three-dimensional artery geometries. The validation of the numerical simulations demonstrates strong alignment with published data.

اللغة الأصليةEnglish
رقم المقال829
دوريةEuropean Physical Journal Plus
مستوى الصوت139
رقم الإصدار9
المعرِّفات الرقمية للأشياء
حالة النشرPublished - سبتمبر 2024
منشور خارجيًانعم

أهداف الأمم المتحدة للتنمية المستدامة

يساهم هذا المخرج في تحقيق أهداف الأمم المتحدة للتنمية المستدامة التالية (SDGs)

  1. Good health and well being
    Good health and well being

بصمة

أدرس بدقة موضوعات البحث “Analysis of biomagnetic blood Carreau hybrid nanofluid flow in stenotic arteries with motile gyrotactic microorganisms: Response surface optimisation'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا