تخطي إلى التنقل الرئيسي تخطي إلى البحث تخطي إلى المحتوى الرئيسي

Hydrophilicity, viscoelastic, and physicochemical properties variations in dental bone grafting substitutes

  • Branko Trajkovski*
  • , Matthias Jaunich
  • , Wolf Dieter Müller
  • , Florian Beuer
  • , Gregory George Zafiropoulos
  • , Alireza Houshmand
  • *المؤلف المقابل لهذا العمل
  • Wound Healing and Oral Diagnostic Research Group
  • University of Sharjah
  • botiss biomaterials GmbH
  • Federal Institute for Materials Research and Testing Berlin
  • Charité – Universitätsmedizin Berlin

نتاج البحث: Article › مراجعة النظراء

57 اقتباسات (Scopus)

ملخص

The indication-oriented Dental Bone Graft Substitutes (DBGS) selection, the correct bone defects classification, and appropriate treatment planning are very crucial for obtaining successful clinical results. However, hydrophilic, viscoelastic, and physicochemical properties' influence on the DBGS regenerative potential has poorly been studied. For that reason, we investigated the dimensional changes and molecular mobility by Dynamic Mechanical Analysis (DMA) of xenograft (cerabone®), synthetic (maxresorb®), and allograft (maxgraft®, Puros®) blocks in a wet and dry state. While no significant differences could be seen in dry state, cerabone® and maxresorb® blocks showed a slight height decrease in wet state, whereas both maxgraft® and Puros® had an almost identical height increase. In addition, cerabone® and maxresorb® blocks remained highly rigid and their damping behaviour was not influenced by the water. On the other hand, both maxgraft® and Puros® had a strong increase in their molecular mobility with different damping behaviour profiles during the wet state. A high-speed microscopical imaging system was used to analyze the hydrophilicity in several naturally derived (cerabone®, Bio-Oss®, NuOss®, SIC® nature graft) and synthetic DBGS granules (maxresorb®, BoneCeramic®, NanoBone®, Ceros®). The highest level of hydrophilicity was detected in cerabone® and maxresorb®, while Bio-Oss® and BoneCeramic® had the lowest level of hydrophilicity among both naturally derived and synthetic DBGS groups. Deviations among the DBGS were also addressed via physicochemical differences recorded by Micro Computed Tomography, Scanning Electron Microscopy, Fourier Transform Infrared Spectroscopy, X-ray powder Diffractometry, and Thermogravimetric Analysis. Such DBGS variations could influence the volume stability at the grafting site, handling as well as the speed of vascularization and bone regeneration. Therefore, this study initiates a new insight into the DBGS differences and their importance for successful clinical results.

اللغة الأصليةEnglish
رقم المقال215
دوريةMaterials
مستوى الصوت11
رقم الإصدار2
المعرِّفات الرقمية للأشياء
حالة النشرPublished - 30 يناير 2018
منشور خارجيًانعم

بصمة

أدرس بدقة موضوعات البحث “Hydrophilicity, viscoelastic, and physicochemical properties variations in dental bone grafting substitutes'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا