تخطي إلى التنقل الرئيسي تخطي إلى البحث تخطي إلى المحتوى الرئيسي

Salivary gland scintigraphy: The use of semiquantitative analysis for uptake and clearance

  • Issa Loutfi*
  • , Madhusoodanan K. Nair
  • , Ali K. Ebrahim
  • *المؤلف المقابل لهذا العمل
  • Mubarak Al-Kabeer Hospital
  • Nuclear Medicine Department
  • Kuwait University

نتاج البحث: Article › مراجعة النظراء

68 اقتباسات (Scopus)

ملخص

Objective: Quantitative analysis of 99mTc-pertechnetate salivary gland scintigraphy has been used in the evaluation of salivary gland function, but so far no one method can be considered optimal for this task. In this study, a semiquantitative method providing 2 functional parameters for objective assessment of salivary gland function by scintillation camera imaging was tested. Methods: Twenty-one patients referred for 99mTc-pertechnetate thyroid scanning were studied. Two patients with salivary complaints were also included. Dynamic imaging of the anterior head using a scintillation camera was started after a bolus intravenous injection of 185 MBq (5 mCi) 99mTc-pertechnetate at 1 frame per 30 s for 30 min. At 15 min after injection, diluted lemon juice was administered orally. Analysis of the dynamic study included time-activity curves of 4 salivary glands (right and left parotid and right and left submandibular). Two parameters of function were defined: uptake rate, taken as the value of the initial slope of the time-activity curve, and washout fraction, which was the relative mobilizable radioactivity from each salivary gland after ingestion of the sialogogue. A parametric image of the washout fraction was also generated. Results: The images showed gradual uptake in the parotid and submandibular glands. Washout was noted immediately after ingestion of the lemon juice. The pattern of the time-activity curve in all glands showed an early fast-rising part followed by a slow-rising component to nearly a plateau within 6-10 min after injection. The mean value of the uptake rate parameter was 0.10 ± 0.09 cps/s. There was no significant difference between the parotid and submandibular glands or the right and left sides. Uptake in the parotid gland was 1.5-2 times that in the submandibular gland. The washout fraction was 1.40 ± 1.60 for the parotid glands and 0.77 ± 0.41 for the submandibular glands (P ± 0.005). Conclusion: The quantitative analysis method including the uptake rate and the washout fraction parameters would enable objective assessment of salivary function and provide a reproducible means for follow-up of functional impairment in certain diseases.

اللغة الأصليةEnglish
الصفحات (من إلى)81-85
عدد الصفحات5
دوريةJournal of Nuclear Medicine Technology
مستوى الصوت31
رقم الإصدار2
حالة النشرPublished - يونيو 2003

بصمة

أدرس بدقة موضوعات البحث “Salivary gland scintigraphy: The use of semiquantitative analysis for uptake and clearance'. فهما يشكلان معًا بصمة فريدة.

قم بذكر هذا