Skip to main navigation Skip to search Skip to main content

An improved method for automated calculation of the water-equivalent diameter for estimating size-specific dose in CT

  • Choirul Anam*
  • , Fahmi Rosydiansyah Mahdani
  • , Winda Kusuma Dewi
  • , Heri Sutanto
  • , Pandji Triadyaksa
  • , Freddy Haryanto
  • , Geoff Dougherty
  • *Corresponding author for this work
  • Department of Physics
  • Universitas Diponegoro
  • Department of Physics
  • Bandung Institute of Technology
  • California State University Channel Islands

Research output: Contribution to journal › Article › peer-review

21 Scopus citations

Abstract

Purpose: The aim of this study is to propose an algorithm for the automated calculation of water-equivalent diameter (Dw) and size-specific dose estimation (SSDE) from clinical computed tomography (CT) images containing one or more substantial body part. Methods: All CT datasets were retrospectively acquired by the Toshiba Aquilion 128 CT scanner. The proposed algorithm consisted of a contouring stage for the Dw calculation, carried out by taking the six largest objects in the cross-sectional image of the patient's body, followed by the removal of the CT table depending on the center position (y-axis) of each object. Validation of the proposed algorithm used images of patients who had undergone chest examination with both arms raised up, one arm placed down and both arms placed down, images of the pelvic region consisting of one substantial object, and images of the lower extremities consisting of two separated areas. Results: The proposed algorithm gave the same results for Dw and SSDE as the previous algorithm when images consisted of one substantial body part. However, when images consisted of more than one substantial body part, the new algorithm was able to detect all parts of the patient within the image. The Dw values from the proposed algorithm were 9.5%, 15.4%, and 39.6% greater than the previous algorithm for the chest region with one arm placed down, both arms placed down, and images with two legs, respectively. The SSDE values from the proposed algorithm were 8.2%, 11.2%, and 20.6% lower than the previous algorithm for the same images, respectively. Conclusions: We have presented an improved algorithm for automated calculation of Dw and SSDE. The proposed algorithm is more general and gives accurate results for both Dw and SSDE whether the CT images contain one or more than one substantial body part.

Original languageEnglish
Pages (from-to)313-323
Number of pages11
JournalJournal of Applied Clinical Medical Physics
Volume22
Issue number9
DOIs
StatePublished - Sep 2021
Externally publishedYes

Keywords

  • CT dose index (CTDI)
  • patient dose
  • size-specific dose estimates (SSDE)
  • water-equivalent diameter (D)

Fingerprint

Dive into the research topics of 'An improved method for automated calculation of the water-equivalent diameter for estimating size-specific dose in CT'. Together they form a unique fingerprint.

Cite this