Abstract
Turbulent forced-convection fluid dynamic simulations were conducted to investigate the impacts of diff erent baffle shapes on the thermal aerodynamic performance of a horizontal two-dimensional channel of rectangular section with wall-mounted baffles and fins. The top wall was put in a constant temperature condition, as the bott om wall was thermally insulated. Two obstacles, having diff erent shapes, i.e., simple and 45o downstream V-shaped, were inserted into the channel and fixed to the upper and lower walls, in a periodically staggered manner. The fluid flow model was governed by the RANS equations and the energy equation. All these equations were discretized by the FVM, handled the pressure-velocity coupling with the SIMPLE discretization algorithm and solved using a CFD technique. This represents a very important issue in the area of shell-and-tube heat exchangers where the flow must be characterized; there is also a need to identify the velocity distribution, as well as the existence and the extension of possible recirculations.
| Original language | English |
|---|---|
| Pages (from-to) | 1781-1818 |
| Number of pages | 38 |
| Journal | Heat Transfer Research |
| Volume | 50 |
| Issue number | 18 |
| DOIs | |
| State | Published - 2019 |
| Externally published | Yes |
Keywords
- Aerodynamics
- Downstream V-shaped baffle
- Finite volume methods
- Flat rectangular fin
- Forced convection
- Heat transfer
- Shell-and-tube heat exchangers
- Turbulent flow
Fingerprint
Dive into the research topics of 'Computational thermal analysis of turbulent forced-convection flow in an air channel with a flat rectangular fin and downstream v-shaped baffle'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver