Skip to main navigation Skip to search Skip to main content

Effect of variation of silicone rubber RTV 52 and bluesil catalyst 60 R composition on bolus material for electron beam radiotherapy application

  • Eko Hidayanto*
  • , Heri Sutanto
  • , Indras Marhaendrajaya
  • , Gede Wiratma Jaya
  • , Zaenal Arifin
  • , Choirul Anam
  • , Lidya Purna Widyastuti Setjadiningrat Kuntjoro
  • , Galih Puspa Saraswati
  • , Geoff Dougherty
  • *Corresponding author for this work
  • Department of Physics
  • Universitas Diponegoro
  • Radiotherapy Installation
  • Ken Saras Hospital
  • California State University Channel Islands

Research output: Contribution to journal › Article › peer-review

4 Scopus citations

Abstract

A bolus is a material equivalent to soft tissue and is directly placed on the skin surface during radiotherapy. It is commonly used to increase the dose on the skin surface in electron beam radiation. A typical material for a bolus is silicone rubber (SR). We made a bolus with dimensions of 17 × 17 × 1 cm3 by varying silicone rubber (SR) RTV 52 and hardening material (bluesil catalyst 60 R) using a simple molded method. We characterized it using a CT scan to find the relative electron density (RED) and examined it using the electron beam of a linear accelerator (LINAC) at energies of 5 and 7 MeV to investigate the percentage of surface dose (PSD). The PSD value is relative to the dose at maximum doses (dmax). The RED value of the bolus was from 1.168 ± 0.021 to 1.176 ± 0.019, higher than the soft tissue (muscle) value of 1.043. The percentage of surface dose (PSD) test at 5 and 7 MeV LINAC energy showed that the highest PSD without using a bolus were 84.79 ± 0.06% and 86.03 ± 0.07%, respectively. With a bolus, the PSD values were 112.52 ± 0.16% and 111.14 ± 0.03%, respectively. The results indicate that bolus fabrication using SR RTV 52 and bluesil 60R is very effective for radiotherapy in the treatment of skin cancer due to an increase in surface dose.

Original languageEnglish
Article number045005
JournalBiomedical Physics and Engineering Express
Volume8
Issue number4
DOIs
StatePublished - Jul 2022
Externally publishedYes

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • bluesil catalyst
  • bolus
  • electron beam
  • silicon rubber

Fingerprint

Dive into the research topics of 'Effect of variation of silicone rubber RTV 52 and bluesil catalyst 60 R composition on bolus material for electron beam radiotherapy application'. Together they form a unique fingerprint.

Cite this