Abstract
This paper addresses the matching of the separately-excited and series DC motors driving pumping loads, to solar cell generators. It is shown that the maximum mechanical power can be obtained at slightly higher voltages and slightly lower currents, compared to the maximum electrical power points on the solar cell generator characteristics, at the different insolation levels. Guide lines to construct the loci of the motor voltage-current points for maximum mechanical power and to determine the optimal motor parameters to match the solar generator are derived, in terms of the mechanical load characteristics and the solar array parameters. Results of applying these design criteria to practical case studies enabled the assessment and comparison of both kinds of motrs, especially as far as the daily utilizable output mechanical energy is concerned. The superiority of the separately-excited motors in such systems is quantitatively indicated. The results are also compared to corresponding information available in the literature.
| Original language | English |
|---|---|
| Pages (from-to) | 465-472 |
| Number of pages | 8 |
| Journal | IEEE Transactions on Energy Conversion |
| Volume | 3 |
| Issue number | 3 |
| DOIs | |
| State | Published - Sep 1988 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 7 Affordable and Clean Energy
Fingerprint
Dive into the research topics of 'Matching of dc motors to photovoltaic generators for maximum daily gross mechanical energy'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver