Skip to main navigation Skip to search Skip to main content

Optimization of L- and C-Shaped Enclosures for Natural Convection Flow: Thermal Performance and Irreversibility Analysis by Using Finite Element Method in FEniCS

  • Department of Mechanical Engineering
  • Amirkabir University of Technology
  • Kuwait College of Science and Technology

Research output: Contribution to journal › Article › peer-review

10 Scopus citations

Abstract

This study provides a comprehensive finite element analysis of natural convection and entropy generation in L-shaped and C-shaped enclosures. The analysis considers a Prandtl number ((Formula presented.)) of (Formula presented.), a Grashof number range of (Formula presented.), and a Rayleigh number range of (Formula presented.). The simulations are conducted using the open-source computational platform FEniCS. The investigation focuses on optimizing geometric parameters to enhance thermal performance while minimizing irreversibility. For L-shaped enclosures, extending the horizontal arm initially intensifies buoyancy-driven circulation and improves heat transfer, but leads to increased entropy production due to viscous dissipation. Beyond a critical length ((Formula presented.)), the benefits diminish and irreversibility decreases due to smoother thermal and flow fields. In contrast, increasing the vertical arm length ((Formula presented.)) improves thermodynamic efficiency by broadening the plume path and promoting uniform mixing, without significantly affecting heat transfer rates. For C-shaped enclosures, optimal thermal performance with moderate entropy generation is observed at narrow and shallow recesses ((Formula presented.)), which sustain a strong, singular circulation cell. As the recess deepens or widens ((Formula presented.)), multiple vortices form, leading to increased irreversibility despite fair heat transfer. Excessive recess dimensions degrade flow and sharply raise entropy generation. Across all configurations, increasing the Rayleigh number ((Formula presented.)) enhances convective heat transfer but also escalates thermal irreversibility, which remains the dominant source of entropy generation over viscous effects. Optimal performance is achieved in L-shaped enclosures with (Formula presented.) and in C-shaped cavities with minimal cutout size, offering a balanced strategy for maximizing natural convection efficiency with reduced thermodynamic losses.

Original languageEnglish
Pages (from-to)183-211
Number of pages29
JournalHeat Transfer
Volume55
Issue number1
DOIs
StatePublished - Jan 2026
Externally publishedYes

Keywords

  • FEniCS simulation
  • entropy generation
  • finite element method (FEM)
  • irreversibility
  • natural convection
  • thermodynamic efficiency

Fingerprint

Dive into the research topics of 'Optimization of L- and C-Shaped Enclosures for Natural Convection Flow: Thermal Performance and Irreversibility Analysis by Using Finite Element Method in FEniCS'. Together they form a unique fingerprint.

Cite this