TY - GEN
T1 - Thermal analysis of a building's roof with cone frustum holes containing PCM
AU - Alawadhi, Esam M.
AU - Alqallaf, Hashem J.
PY - 2010
Y1 - 2010
N2 - The thermal effectiveness of a building's roof with Phase Change Material (PCM) is presented in this paper. The considered model consists of a concrete slab with vertical cone frustum holes filled with PCM. The objective of incorporating the PCM into the roof structure is to utilize its high latent heat of fusion to reduce the heat gain during the energy demand peak hours by absorbing the through the melting process in the roof before it reaches the indoor space. The problem is numerically solved in a three-dimensional space using the finite element method. The thermal effectiveness of the proposed roof-PCM system is determined by comparing the heat flux at the indoor surface to a roof without the PCM during typical working hours. A parametric study is conducted to assess the effect of the cone frustum geometry, as well as, the PCM's type. The results indicate that the heat flux at the indoor surface of the roof can be reduced up to 39% when the PCM is incorporated and a conical geometry for the PCM shows the best thermal performance.
AB - The thermal effectiveness of a building's roof with Phase Change Material (PCM) is presented in this paper. The considered model consists of a concrete slab with vertical cone frustum holes filled with PCM. The objective of incorporating the PCM into the roof structure is to utilize its high latent heat of fusion to reduce the heat gain during the energy demand peak hours by absorbing the through the melting process in the roof before it reaches the indoor space. The problem is numerically solved in a three-dimensional space using the finite element method. The thermal effectiveness of the proposed roof-PCM system is determined by comparing the heat flux at the indoor surface to a roof without the PCM during typical working hours. A parametric study is conducted to assess the effect of the cone frustum geometry, as well as, the PCM's type. The results indicate that the heat flux at the indoor surface of the roof can be reduced up to 39% when the PCM is incorporated and a conical geometry for the PCM shows the best thermal performance.
UR - https://www.scopus.com/pages/publications/84860305081
U2 - 10.1115/ES2010-90482
DO - 10.1115/ES2010-90482
M3 - Conference contribution
AN - SCOPUS:84860305081
SN - 9780791843949
T3 - ASME 2010 4th International Conference on Energy Sustainability, ES 2010
SP - 393
EP - 398
BT - ASME 2010 4th International Conference on Energy Sustainability, ES 2010
T2 - ASME 2010 4th International Conference on Energy Sustainability, ES 2010
Y2 - 17 May 2010 through 22 May 2010
ER -