Abstract
The alternating aerobic-anoxic (AAA) process offers many advantages for wastewater treatment and sludge digestion. Laboratory scale experiments were conducted to investigate the feasibility of using pH as a real-time control parameter for this process. Several well defined control points on the pH curve were identified, e.g., ammonia valley and nitrate apex. These points were directly related to the alternating nitrification and denitrification reactions in the process, and were found to be consistent with those previously identified using ORP. Although both pH and ORP can be used as real-time control parameters, pH provides several additional advantages over ORP. Based on these findings, real-time control strategies (fixed pH setpoints and dynamic pH control) were developed and tested. Results from laboratory scale AAA sludge digestion using fixed pH setpoints (6-8) indicated that 36% MLVSS reduction, 39% TN reduction and almost 48% saving in aeration energy was achieved after 300 hrs of digestion.
| Original language | English |
|---|---|
| Pages (from-to) | 159-168 |
| Number of pages | 10 |
| Journal | Water Science and Technology |
| Volume | 30 |
| Issue number | 4 pt 4 |
| DOIs | |
| State | Published - 1994 |
| Event | Proceedings of the 17th Biennial Conference of the International Association on Water Quality. Part 1 - Budapest, Hung Duration: 24 Jul 1994 → 30 Jul 1994 |
UN SDGs
This output contributes to the following UN Sustainable Development Goals (SDGs)
-
SDG 6 Clean Water and Sanitation
Keywords
- Alternating aerobic-anoxic operation
- Ammonia valley
- Endogenous nitrate respiration
- Nitrate apex
- Nitrogen removal
- ORP
- pH
- Real-time computer control
- Sludge digestion
- Wastewater treatment
Fingerprint