Skip to main navigation Skip to search Skip to main content

Using pH as a real-time control parameter for wastewater treatment and sludge digestion processes

  • I. A. Al-Ghusain*
  • , J. Huang
  • , O. J. Hao
  • , B. S. Lim
  • *Corresponding author for this work
  • Kuwait University

Research output: Contribution to journal › Conference article › peer-review

72 Scopus citations

Abstract

The alternating aerobic-anoxic (AAA) process offers many advantages for wastewater treatment and sludge digestion. Laboratory scale experiments were conducted to investigate the feasibility of using pH as a real-time control parameter for this process. Several well defined control points on the pH curve were identified, e.g., ammonia valley and nitrate apex. These points were directly related to the alternating nitrification and denitrification reactions in the process, and were found to be consistent with those previously identified using ORP. Although both pH and ORP can be used as real-time control parameters, pH provides several additional advantages over ORP. Based on these findings, real-time control strategies (fixed pH setpoints and dynamic pH control) were developed and tested. Results from laboratory scale AAA sludge digestion using fixed pH setpoints (6-8) indicated that 36% MLVSS reduction, 39% TN reduction and almost 48% saving in aeration energy was achieved after 300 hrs of digestion.

Original languageEnglish
Pages (from-to)159-168
Number of pages10
JournalWater Science and Technology
Volume30
Issue number4 pt 4
DOIs
StatePublished - 1994
EventProceedings of the 17th Biennial Conference of the International Association on Water Quality. Part 1 - Budapest, Hung
Duration: 24 Jul 1994 → 30 Jul 1994

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 6 - Clean Water and Sanitation
    SDG 6 Clean Water and Sanitation

Keywords

  • Alternating aerobic-anoxic operation
  • Ammonia valley
  • Endogenous nitrate respiration
  • Nitrate apex
  • Nitrogen removal
  • ORP
  • pH
  • Real-time computer control
  • Sludge digestion
  • Wastewater treatment

Fingerprint

Dive into the research topics of 'Using pH as a real-time control parameter for wastewater treatment and sludge digestion processes'. Together they form a unique fingerprint.

Cite this